Skip to content

Output Audio to DA Converters

Single sytem

If you are working with one machine it is relatively straight forward to setup audio output with a digital-analog converter.

  1. Run a optical cable from the sound card on the Disguise system into your DA converter.
  2. Set up the DA to receive sync clock from external device.

You should now have 1-8 channels of analogue audio coming out of your DA converter.

Multiple systems

If you are having a backup (understudy) there are 2 ways to do:

  1. Do as described above utilizing a dedicated DA for the master and a dedicated DA for the understudy.
  2. Synchronise multiple machines to one DA or a Mixing Desk.

In the scenario of multiple machines and one DA, the audio sample clocks of the master and understudy both needs to be synchronised with the DA converter.

How to set up multiple systems

Your external DA is going to be the audio sync clock master so make sure the clock source is internal You will probably also have to set your correct sample rate and bit depth​.

Your RME settings in your machine should be set to Clock source: ADAT IN, however it should auto detect if not otherwise is specified.

Both of the optical cables needs to be connected; one is for signal and one is for sync.

The bottom outlet (grey) is the signal output from the Disguise system and goes into input on the DA converter.

The output on the DA converter (sync) is going into the top input on the Disguise system (Black).

You should see in the RME settings menu on the Disguise system that it is receiving sync signal over the optical cable.

Repeat this step for the understudy as well and you should be good to go.

Troubleshooting

Audio playing inDesigner/windows but no audio is converted in the DA convertor or very small sporadic instances of audio is coming out of the DA.

  • Check the sample rate and bit depth of the entire signal path and make sure they are all set the same parameters (44.1/48 16 bit)

Clicks and pops are heard in the audio from either of the machines

  • The audio sampling is not synced correctly, please check the entire signal path for synchronization e.g. ADAT clock internal on, clock receive ADAT in.